Back to Top

1
Hi, Guest!
Produk atau jasa ini sudah tidak dijual, silakan hubungi perusahaan bersangkutan untuk keterangan lebih lanjut.
  • SP-AA 4000 SPECTRUM INSTRUMENT GmbH GERMANY

SP-AA 4000 SPECTRUM INSTRUMENT GmbH GERMANY

Update Terakhir
:
15 / 11 / 2022
Min. Pembelian
:
1 Set

Harga

Rp. 580.000.000
Anda butuh alat laboratorium dan reagents microbiology, segera hubungi Perusahan kami" . PT. SUMBER ARUM ABADI adalah distributor atau subdistributor supplier importir resmi Indonesia yang bergerak dibidang alat Laboratorium dan Microbiology di Surabaya Jawa Timur Indonesia , Dengan Merek Sebagai berikut : acumedia from neogen corp USA, merck KGaA Germany, sigma aldrich USA, waters For HPLC Ireland, ridacount, copan italy, biooscientific, difco, atago, bd, bbl, memmert, hirayama, atago, thermo scientific, thermolyne, funke gerber germany, warring, hach usa, olympus, seedburo, all american, vwr, sibata, horiba, uetech, yellowline, wildco, takemura, ATCC gibson laboratories Inc., As-One, pyrex, brand, biohit, axygen scientific, AZ Taiwan, boeco germany, gast vacuum pump, optika italy Microscope, motic Microscope, interscience france, hettich, and balance Japan, Ohaus Balances and Scale USA, mettler toledo balance USA, presica balance taiwan, kern balances germany, eppendorf, testo, velp scientifica, KNF neuberger, nabertherm vaccuum Pumps Germany, advantec toyo kaisha Ltd. Japan, kett Science And Sensing USA, eppendorf jerman, hanna instrument, IKA, hanil centrifuge taiwan, kern balances germany, GFL water still USA, acumedia, biogen, seward, wildco, haws, seward uk, witega germany, microessential, yazumi, neofilm neogen usa, pobel water stills spain, parafilm m bemis company inc. usa, sanita-kun japan, spectrum instruments australia, analytik jena germany, funke gerber germany, organomation usa, gibertini italy, stat fax 4200 microplate reader, stat fax 4700 microwell reader, automated elisa analyzer iea, labomed in. usa, deltatrak usa, miccroessentiallab usa dll

Detail SP-AA 4000 SPECTRUM INSTRUMENT GmbH GERMANY

1 unit

SP-AA 4000 SPECTRUM

 

 

 

High light throughput Single Beam and True Double Beam. The SP-AA 4000 is a fully automated computer controlled Flame AAS instrument featuring an 8-lamp turret, automatic gas box and automatic burner height setting. The majority of samples will run smoothly with this instrument, if the stored default methods are applied. In case of unique challenges our application experts will take personal responsibility for responding to the customer”s needs.

 

 

 

Monochromator

Czerny-Turner- type with 2 focal lengths at 355.8 and 345.6 mm, automated wavelength selection and slit selection. The system provides a true double beam mode.

 

Wavelength range

185 – 900 nm

 

Modes of Operation

Atomic Absorption and Atomic Emission

 

Grating

Holographic grating with 1800 lines/mm

 

Detector

Wide range UV sensitive photomultiplier tube

 

Slits

Automated 6 slit selection 0.1; 0.2; 0.5; 0.7; 1.4 and 2.0 nm

 

Lamp

Automated 8-lamp turret with independent lamp power supply to each lamp and with two heating circuits for preheating lamp operation

 

Background Correction

Deuterium (D2) Background Correction and Smith-Hieftje(Self-absorption)Background Correction.

 

 

 

 

Flame System

 

 

Burner-Nebulizer System

All-titanium 100 mm and 50 mm burners are available for air / acetylene gases and for acetylene / nitrous oxide flame. Adjustable nebulizer with internal Platinum / Iridium capillary, PEEK Nozzle and fixed ceramic impact bead are supplied as standard. SP-AA 4000 features automated setting of burner height for each elements.

 

Spray Chamber

The PPS (Polyphenylene Sulfide)  spray chamber is used for both aqueous and organic solution

 

Gas Controls

Software controlled gas box allows the automatic setting of gas flows for each element.Acetylene flow is automatically adjusted prior to the oxidant change when switching to or from nitrous oxide-acetylene operation.

 

Safety Function

Interlocked safety system prevents selection of the nitrous oxide flame if the nitrous oxide burner is not fitted. Sensor controls for protection to use the incorrect burner head and check the siphon system. In case of pressure failure of fuel or oxidant gas, or power failure, safety interlocks will shut down the gases automatically in the right order.

1 Set

Hydride System

-

The Hydride system is a continious flow  technique  for Determine Hg, As, Se, Sb, Te, Sn, Bi

-

Range concentration analyse at ppb

-

The Hg will be Determin ed with the cold Vapour technique

-

The System has the gas flow control including two peristaltic pump for supplay the reagen, acid, and sample

 

 

1x

Burner Head Acetylene/Nitrous Oxide, 50mm

1x

Burner Head Acetylene/Air Flame,100mm

8x

Hollow Cathode Lamps : Na,K,Mg,Ca,Pb,Hg,Cd,As

8x

Standar Solution : Na,K,Mg,Ca,Pb,Hg,Cd,As

1x

Regulator Acetylene

1x

Regulator N2O

1x

Regulator Argon

1x

Gas Acetylene + Cylinder

1x

Gas N2O + Cylinder

1x

Gas Argon + Cylinder

1x

Blower, Vent, & Flexible Ducting

1 unit

Oiless Compressor

1 unit

Software SPWIN-AAS

1 Set

Control & Evaluation unit,  Intel (R) Corei5 (TM) RAM 4 GB 500 GB, USB, Optical Mouse, USB Keyboard, DVDRW integrated video, LED, monitor 18.5”

1 unit

Printer Laser Jet

Tampilkan Lebih Banyak
Kontak Kami